Battery Communicator and Controller for CPM
(Code:BATGWL0109)
| Stock availability: | |||
|---|---|---|---|
| Main warehouse | External warehouse | External warehouse 2 | |
| >10pcs | 1-2 days | 1-2 days | |
| Delivery time | |||
| List price: | 46.47 EUR |
|---|---|
| Code | BATGWL0109 |
| PN | BCC |
| EAN | 8594199020090 |
| Warranty | 12 months |
| Support | bat@100mega.cz |
| Brand |
IQTRONIC
IQtronic technologies Europe s.r.o.
Roháčova 145/14, 13000 Praha 3, Česko
libor.konecny@iqtronic.com
www.mikrovlny.cz
|
The key features
- It contains a 10 Mbps LAN interface for remote reading and writing of parameters to the CPM and two programmable potential-free switching NO/NC relays max 30V / 1A AC/DC.
- It's configurable and controllable using any web browser on tablets, phones, or notebooks.
Application possibilities
- One-time or periodic reading and writing of values to and from CPM via LAN interface and TCP/IP protocol (HTTP + XML), in particular:
- Emergency shutdown, switching on and resetting the entire CPM.
- Reading the voltage of all cells connected to the CPM and the total battery voltage.
- Reading the Umax and Umin output conditions on the CPM (closed/open).
- Displaying the last event on the CPM (voltage Umin, Umax, Uemergency),
- Remote closing/opening of output Terminals 1-4 Umax and Umin and Emergency on CPM,
- Remote change of Umax and Umin voltage limits protecting the battery against deep discharging or overcharging,
- 2 additional programmable switching NO/NC potential-free relays, automatic state change possible according to battery voltage, according to the highest difference between cells or in the case of communication failure. Manual switching via www is possible at any time,
- Wide range of supply voltage 9-65V, also using passive PoE.
Description of the main parts of the board
- RESET - to reset the BCC module to the factory default settings
- LAN CONNECTOR - periodic reading and writing of values to and from CPM via LAN interface
- POWER SUPPLY - 9 – 65V power supply via terminal block
- LED INDICATORS - the board is switched on, establishing communication with CPM, ethernet interface and the states of the two relays (C1 and C2). The lights are on when they are switched, the lights are off when they are in their normal state.
- RELAYS - Relays 1 and 2 can be set arbitrarily, see the user manual (they can react to Udiff, Ubatt, loss of communication ...).
- COM.i2c - logic connection to CPM, communication.
Basic connection of inputs and outputs
- COM.i2c – Communication bus between BCC and CPM module.
- START CPM – It‘s possible to remotely diagnose the battery
- RESET CPM – If necessary, switch on or reboot the CPM BMS module, i.e., reconnect the load and/or charger. It isn‘t necessary to switch off the CPM via relays and terminals.
BCC installation examples
Remote reboot or turning on the CPM board
Charger and load
Local semaphore and voltage record at thingspeak.com
- More examples of possible connection you can find in the manual.
| Brand | |
| Type specification: | Electrical accessories |
| Manufacturer: | IQTRONIC |
| Power supply | |
| Input voltage (V): | 9-65 |
| Usage and purpose | |
| Type of accessories: | control unit |
| Physical properties | |
| Length (mm): | 75 |
| Weight (kg): | 0.1 |
| Width (mm): | 57 |
| Height (mm): | 19 |
| Additional equipment and features | |
| LED indication: | yes |
Product price timeline.
Logistics parameters
- Weight: 0.078 kg
- Weight of packaging: 0.042 kg
- Width: 12 cm
- Height: 8 cm
- Depth: 5.5 cm
- Volume: 528 cm3
- Qty: 1 ks



Personal pickup
TNT Carrier