BMS Easy - Module for LiFePO4 cells temperature protection
(Code:BATGWL0041)
| Stock availability: | ||
|---|---|---|
| Main warehouse | External warehouse | External warehouse 2 |
| Usual availability approx 2 weeks | ||
| List price: | 22.41 EUR |
|---|---|
| Code | BATGWL0041 |
| PN | BMS-EASY-T |
| EAN | |
| Warranty | 12 months |
| Support | bat@100mega.cz |
| Brand |
OK9RKL
OK9RKL s.r.o.
Na Truhlářce 2014/15, 18000 Praha 8, Česko
richardkloubsky@gmail.com
www.ok9rkl.cz
|
Module for protection of a battery cell or a block of cells against overheating. EasyT modules can be functionally connected together with EasyV modules to create basic protection for 12V, 24V, 48V, etc. batteries. One EasyT module can connect up to two thermal sensors.
Function:
If the temperature of the monitored cell or block of cells is lower than the specified operational maximum, the output relay of the module is connected to the COM - NO position, and the signaling LED blinks at intervals of approximately 3 seconds. If the temperature rises above the permissible limit, the relay switches to the COM - NC position, and the LED stops blinking.
- Simple, durable, and reliable electrical design (without SW)
- Easy connection and installation of the module
- Output galvanic isolation (bistable relay)
- Galvanically separated inputs for common reset of modules (optocoupler)
Applications:
- Basic protection for simple systems (backup power, caravans, cottages, etc.)
- Dual (backup) protection for advanced BMS systems
- Dual warning system for control systems
- Meets the condition of automatic shutdown in case of failure
In combination with the BMS Easy module, it meets the basic requirements of the IEC 62619 standard for battery system protection.
Basic Connection of Easy and Easy T Modules for Voltage and Temperature Protection
If the cell goes out of the allowed voltage range or the temperature of the block of cells exceeds the allowed temperature, the relay on the corresponding Easy module switches to the NC position, the contactor KM1 loses power on the coil, and disconnects the power.

Basic Battery Protection According to IEC 62619 with an External Control Circuit Power Supply
For advanced systems, there is an independent backup power supply of 24 V DC for control circuits. It can be used to power the EasyT module, power contactor, and its auxiliary relay.

BASIC SPECIFICATIONS
Power Supply Voltage: 4.5–30 V
Own Consumption: max. 8 mA
Relay Switching at Tmax: up to 55 °C
Max. Relay Switching Power (DC): 30 V/1 A, 60 V/0.5 A, 200 V/0.1 A
Dielectric Strength of the Relay: 1000 V RMS
Maximum Umax Voltage Between the Temperature Sensor and the Board Power: 500 V
Input Voltage of Remote Reset/Start: 9–200 V (DC, AC)
Relay Consumption during Start/Reset Pulse: 7.3 mA
Dimensions: 60 × 40 × 23 mm
Weight: 22 g
Scheme:

| Brand | |
| Type specification: | Electrical accessories |
| Manufacturer: | OK9RKL |
| Physical properties | |
| Depth (mm): | 40 |
| Weight (kg): | 0.022 |
| Dimensions: | 60 × 35 mm |
| Width (mm): | 60 |
| Height (mm): | 23 |
Product price timeline.
Logistics parameters
- Weight: 0.024 kg
- Width: 6 cm
- Height: 2 cm
- Depth: 4 cm
- Volume: 48 cm3
- Qty: 1 ks



Personal pickup
TNT Carrier