Hybrid inverter Victron MultiPlus-II GX 48V/3000VA/35A-32A
(Code:SOPGWL0284)
| Stock availability: | |||
|---|---|---|---|
| Main warehouse | External warehouse | External warehouse 2 | |
| 1pcs | 1-2 days | 1-2 days | |
| Delivery time | |||
| List price: | 635.90 EUR |
|---|---|
| Code | SOPGWL0284 |
| PN | PMP482306000 |
| EAN | 8719076046448 |
| Warranty | 12 months |
| Brand |
VICTRON
Victron Energy B.V.
De Paal 35, 1351 JG Almere, Nizozemsko
lpopescu@victronenergy.com
www.victronenergy.cz
|
A MultiPlus-II with LCD and GX functionality
The MultiPlus-II GX integrates a MultiPlus-II inverter/charger and a GX device with a 2x 16 character display.
Display and Wi-Fi
The display reads battery, inverter and solar charge controller parameters.
The same parameters can be accessed with a smartphone or other Wi-Fi enabled device.
GX device
The integrated GX device includes:
• A BMS-Can interface (This can be used to connect to a compatible CAN-bus managed battery. Note that this not a VE.Can compatible port.)
• A USB port
• A Ethernet port
• A VE.Direct port
Applications
The MultiPlus-II GX is intended for applications where additional interfacing with other products and/or remote monitoring is required, such as on-grid or off-grid energy storage systems and certain mobile applications.
Parallel and three phase operation
Only one GX unit is needed in case of Parallel and three phase operation.
ZÁKLADNÍ SPECIFIKACE
Power (at 25 °C): 3000 VA (2400 W)
Maximum efficiency: 95 %
Interfaces: BMS-Can, USB, Ethernet, VE.Direct, Wi-Fi
DC Input voltage range (inverter): DC 38-66 V
Output (inverter): AC 230 V (50 Hz, can be adjusted to 60 Hz)
AC Input (charger): AC 187-265 V (45–65 Hz)
Output Voltage (charger): 57.6 / 55.2 / 52.8 V (depending on charging phase)
Weight: 19 kg
Dimensions: 506 x 275 x 147 mm
1. Standard marine, mobile or off-grid application
Loads that should shut down when AC input power is not available can be connected to a second output (not shown). These loads will be taken into account by the PowerControl and PowerAssist function in order to limit AC input current to a safe value when AC power is available.

2. Standard mobile or off-grid application with external current sensor
Maximum current sensing range is 50 A (resp. 100 A).

3. Grid parallel topology with MPPT solar charge controller
The MultiPlus-II will use data from the external AC current sensor (must be ordered separately) or power meter to optimise self-consumption and, if required, to prevent grid feed. In case of a power outage, the MultiPlus-II will continue to supply the critical loads.

4. Grid in-line topology with PV inverter
PV power is directly converted to AC. The MultiPlus-II will use excess PV power to charge the batteries or to feed power back into the grid, and will discharge the battery or use power from the grid to supplement a shortage of PV power. In case of a power outage, the MultiPlus-II will disconnect the grid and continue to supply the loads.

| Brand | |
| Type specification: | Voltage converter (15-50 kg) |
| Manufacturer: | VICTRON |
| Technical specification | |
| Max. operating temperature (°C): | 65 |
| Min. operating temperature (°C): | -40 |
| Output voltage shape: | sinus |
| Power supply | |
| Frequency (Hz): | 45-65 |
| Phase: | single-phase |
| Input Voltage (V): | 187 - 265 (AC) |
| Input Voltage (V): | 38 - 66 (DC) |
| Output voltage (V): | 230 (AC) |
| Output voltage (V): | 57,6 / 55,2 / 52,8 (DC) |
| Output Power (W): | 2400 |
| Physical properties | |
| Weight (kg): | 19 |
| Dimensions: | 506 × 275 × 147 mm |
| Additional equipment and features | |
| PPDS certificate: | yes |
Product price timeline.
Logistics parameters
- Weight: 20.6 kg
- Weight of packaging: 1.31 kg
- Width: 58.4 cm
- Height: 24 cm
- Depth: 34.7 cm
- Volume: 48635.5 cm3
- Qty: 1 ks



Personal pickup
TNT Carrier